Development of a candidate reference measurement procedure by ID-LC-MS/MS for total tau protein measurement in cerebrospinal fluid (CSF)

Résumé

Objectives: In clinical pratice, tau protein measurement generally relies on immunoassays (IAs), whose major drawback is the lack of results comparability due to differences in selectivity and/or calibration. This underlines the importance of establishing a traceability chain for total tau (t-tau) measurements. The objective of this work is to develop a higher order candidate reference measurement procedure (RMP) for the absolute quantification of t-tau in cerebrospinal fluid (CSF). Methods: To calibrate the candidate RMP and establish metrological traceability to the SI units, a primary calibrator consisting in a highly purified recombinant protein was sourced. Its purity was evaluated by liquid chromatography coupled with high resolution mass spectrometry (LC-HRMS) and the protein mass fraction in solution was certified by amino acid analysis (AAA). An isotopically-labelled homologue was obtained to develop a candidate RMP by isotope dilution mass spectrometry (IDMS) for t-tau absolute quantification in CSF. Calibration blends and quality control (QC) materials were gravimetrically prepared and subjected to the same preparation workflow as CSF samples, followed by LC-HRMS analysis in Parallel Reaction Monitoring (PRM) mode. Results: A primary calibrator has been developed and an IDMS candidate RMP has been validated for CSF t-tau. The candidate RMP was used to certify t-tau concentration in three pools of CSF (low, medium, high). Conclusions: The candidate RMP will pave the road towards global standardization of CSF t-tau measurements. Together with commutable Certified Reference Materials (CRMs), it will allow evaluating and improving the accuracy and comparability of results provided by IAs.
Fichier principal
Vignette du fichier
10.1515_cclm-2022-1250.pdf (1.63 Mo) Télécharger le fichier
Origine Publication financée par une institution
licence

Dates et versions

hal-04598085 , version 1 (03-06-2024)

Licence

Identifiants

Citer

Chiara Giangrande, Hélène Vaneeckhoutte, Amandine Boeuf, Béatrice Lalere, Christophe Hirtz, et al.. Development of a candidate reference measurement procedure by ID-LC-MS/MS for total tau protein measurement in cerebrospinal fluid (CSF). Clinical Chemistry and Laboratory Medicine, 2023, 61 (7), pp.1235-1244. ⟨10.1515/cclm-2022-1250⟩. ⟨hal-04598085⟩
3 Consultations
1 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More