Validation of Tropospheric Emission Spectrometer (TES) nadir ozone profiles using ozonesonde measurements - Laboratoire de l'Atmosphère et des Cyclones Accéder directement au contenu
Article Dans Une Revue Journal of Geophysical Research: Atmospheres Année : 2008

Validation of Tropospheric Emission Spectrometer (TES) nadir ozone profiles using ozonesonde measurements

Ray Nassar
  • Fonction : Auteur
Jennifer A. Logan
  • Fonction : Auteur
Helen M. Worden
  • Fonction : Auteur
Inna A. Megretskaia
  • Fonction : Auteur
Kevin W. Bowman
  • Fonction : Auteur
Gregory B. Osterman
  • Fonction : Auteur
David W. Tarasick
  • Fonction : Auteur
Shermane Austin
  • Fonction : Auteur
Hans Claude
  • Fonction : Auteur
Manvendra K. Dubey
  • Fonction : Auteur
Wayne K. Hocking
  • Fonction : Auteur
Bryan J. Johnson
  • Fonction : Auteur
Everette Joseph
  • Fonction : Auteur
John Merrill
  • Fonction : Auteur
Gary A. Morris
  • Fonction : Auteur
Mike Newchurch
  • Fonction : Auteur
Samuel J. Oltmans
  • Fonction : Auteur
F. J. Schmidlin
  • Fonction : Auteur
Holger Vömel
  • Fonction : Auteur
David N. Whiteman
  • Fonction : Auteur
Jacquelyn C. Witte
  • Fonction : Auteur

Résumé

We compare Tropospheric Emission Spectrometer (TES) version 2 (V002) nadir ozone profiles with ozonesonde profiles from the Intercontinental Chemical Transport Experiment Ozonesonde Network Study, the World Ozone and Ultraviolet Data Center, the Global Monitoring Division of the Earth System Research Laboratory, and the Southern Hemisphere Additional Ozonesonde archives. Approximately 1600 coincidences spanning 72.5°S-80.3°N from October 2004 to October 2006 are found. The TES averaging kernel and constraint are applied to the ozonesonde data to account for the TES measurement sensitivity and vertical resolution. TES sonde differences are examined in six latitude zones after excluding profiles with thick high clouds. Values for the bias and standard deviation are determined using correlations of mean values of TES ozone and sonde ozone in the upper troposphere (UT) and lower troposphere (LT). The UT biases range from 2.9 to 10.6 ppbv, and the LT biases range from 3.7 to 9.2 ppbv, excluding the Arctic and Antarctic LT where TES sensitivity is low. A similar approach is used to assess seasonal differences in the northern midlatitudes where the density and frequency of sonde measurements are greatest. These results are briefly compared to TES V001 ozone validation work which also used ozonesondes but was carried out prior to improvements in the radiometric calibration and ozone retrieval in V002. Overall, the large number of TES and sonde comparisons indicate a positive bias of approximately 3-10 ppbv for the TES V002 nadir ozone data set and have helped to identify areas of potential improvement for future retrieval versions.
Fichier principal
Vignette du fichier
2007JD008819.pdf (1.62 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-00961630 , version 1 (03-09-2021)

Licence

Copyright (Tous droits réservés)

Identifiants

Citer

Ray Nassar, Jennifer A. Logan, Helen M. Worden, Inna A. Megretskaia, Kevin W. Bowman, et al.. Validation of Tropospheric Emission Spectrometer (TES) nadir ozone profiles using ozonesonde measurements. Journal of Geophysical Research: Atmospheres, 2008, 113 (D15), pp.D15S17. ⟨10.1029/2007JD008819⟩. ⟨hal-00961630⟩
269 Consultations
90 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More